Site Sentinel
®
16 Installation and Operation Manual
SETUP
Status
Input Status Messages: Used to identify the status input source.
Alarms OFF: This option enables the sending of an email when the
input is OFF.
Alarms ON: This option enables the sending of an email when the
input is ON.
Email Addresses: This allows you to configure up to 8 emails to be sent
whenever the input is turned ON or OFF.
Normal Signal Level: This drop-down configures the input signal to be normal-
ly High or normally Low. This is used to determine if an
input is ON or OFF.
NOTE: When the "Normal signal level" is set to HIGH = NO voltage is
applied to the input (WET or no closure when configured for DRY), it's con-
sidered OFF, when voltage IS applied (WET or completed closure set to DRY)
to the input, it considered ON.
Log Device: This enables the email logging of this device.
Delay time: The delay is in (0 to 999) seconds. This option specifies the wait
time from when a value is out of range before an alarm is acti-
vated.
Alarm LED: User defined color of LED on the Monitor and
Control page when in an alarm condition.
NOTE: After any item has been changed, you MUST press the “Save Settings”
button for your changes to be saved.